PRODUCTION DIMENSIONS

It can be produced specially according to request

Metallic Materials

ST 37

 

 

Height

2800 mm Parapet Included.

Glass wool

TS 901

Polystyrene Foam

TS EN 7316

TECHNICAL DATA

Earthquake Conditions

1st degree

Outer Wall Transmission Coefficient

K:0.50 Kcal/m2hc

Climate Conditions

3. Climate Zone

Roof Transmission Coefficient

K:0.69 Kcal/m2hc

Snow Load

80 Kg/m²

Floor Heat Conduction Coefficient

K:0.68 Kcal/m2hc

Wind speed

80 Km/Hour (provided that it is fixed to the ground)

Chassis Load Capacity

200 Kg/m²

FLOOR

Floor Coating

Fibercement or cementitious particle board is used as floor covering. PVC Mineflo with 2 mm thickness is used as floor covering.

OUTER WALL

System

The carcass is made with the help of specially shaped profiles.

Exterior Coating

The outer surface coating is optionally covered with 12 mm thick Taşonit or Wood patterned fibercemet or cemented chipboards.

Inner Surface Coating

6 mm thick fibercemet or cemented chipboards are used for the inner surface coating. (Inner surface coating PVC paneling is used in metropolitan cabins with WC.)

Wall Insulation

With 40 mm thickness, 10 kg/m³ polystyrene foam (EPS) fire class B1; It is made with heat-insulated complete, healthy and safe materials.

INNER WALL

System

The carcass is made with the help of specially shaped profiles.

Inner Surface Coating

8 mm thick fibercemet or cemented chipboards are used for the inner surface coating. (Inner surface coating PVC paneling is used in metropolitan cabins with WC.)

Wall Insulation

With 40 mm thickness, 10 kg/m³ polystyrene foam (EPS) fire class B1; It is made with heat-insulated complete, healthy and safe materials.

ROOF

Roof System

It is produced with the help of specially shaped construction and carrier one-piece profiles, and it is made with 20 cm eaves and 40 cm high parapet. Rain water is discharged through corner columns.

Roof Insulation

The 80 mm thick mattress is made of glass wool (14 kg/m³).

Inner Surface Coating

Inner surface ceiling covering PVC wainscot is used.

(Optional 8 mm concrete board can be used.)

(Interior surface ceiling covering PVC panelling is used in metropolitan cabins with WC.)

External Surface Coating

0.50 mm thick 27 mm *200 mm deep Natural Trapezoidal Galvanized Sheet.

DOORS

Exterior Door

It is TSE certified white PVC joinery in 90*200 cm dimensions.

Inner Door

It is an American wooden door measuring 80*200 cm.

WINDOWS

Window

It is TSE certified white PVC joinery in 120*100 cm dimensions.

Frames

PVC moldings are used on the inner edges of the windows.

Window

4 12 4 double glazing is used.

PAINTS

Exterior

Exterior surfaces are painted in the desired color with silicone-based exterior paint.

Door Frames

1 coat Rapid primer painted.

Metal Parts

1 coat of Rapid primer paint is applied.

ELECTRICAL INSTALLATION (Flush mounted)

System

Each room has a switch, a socket, and a telephone socket. In addition, spot luminaires are used for lighting at the four corners of the eaves.

Cable

Electrical power is 2000 W 220 Volts, 3x2.5 mm for sockets, 2x1.5 mm for lighting, TSE certified NYM cables are used.

Lighting Fixture

TSE certified torus luminaire is used for lighting.

Sockets and Switches

TSE certified materials are used.

SANITARY INSTALLATION

Vitrifiye

TSE certified materials are used.

Clean Water Installation

TSE certified PPRC materials are used.

Waste Water System

TSE certified PVC material is used.

EXTERNAL CONNECTIONS

It is the customer's responsibility to pour concrete 20 cm more than the cabin dimensions, install the cabin on the ground, and make electricity, clean water and waste water connections.

LIFTING FUNCTION

Containers can be lifted and lowered from four corners with lifting eyebolts and steel ropes.